Test Item
|
Test condition
|
Standard
|
High Temperature Storage Test
|
Ta=80±2℃ 240 hours.
|
IEC 61747-5
|
High Temperature Operation Test
|
Ta=70±2℃ 240 hours.
|
IEC 61747-5
|
Low Temperature Storage Test
|
Ta= -30±2℃ 240 hours.
|
IEC 61747-5
|
Low Temperature Operation Test
|
Ta= -20±2℃ 240 hours.
|
IEC 61747-5
|
High Temperature/Humidity Storage Test (1)
|
Ta=60±2℃ RH=95±2% 240 hours.
|
IEC 61747-5
|
High Temperature/Humidity Operation Test (2)
|
Ta=40±2℃ RH=95±2% 240 hours.
|
IEC 61747-5
|
Temperature cycling
|
65℃ ~ -10℃ 95%~80%R.H 24 Hours
|
IEC 61747-5
|
Thermal Shock Test
|
-35℃ó 80℃ 10 cycle. 30 mins dwell at high/low temp.
|
IEC 61747-5
|
Vibration Test
|
10~500Hz XYZ axial 1hours.
|
IEC 61747-5
|
E.S.D Test (MODULE)
|
Contact model:PASS ±2KV (AT PAD)
Air discharge :PASS ±6KV
|
IEC 61747-5
|